What happens in this clip
The video explains building code requirements for stair landings, focusing on minimum width and depth. For homes or buildings with an occupant load of less than 50 people, a landing generally needs to be at least 36 inches by 36 inches (3'x3'). For buildings with an occupant load exceeding 50 people, the minimum width and depth increase to 44 inches (3'8"). Crucially, the landing must be at the top and bottom of every stairway. The video also highlights an exception for very long stairways (over 12 feet vertical height) which require an intermediate landing. The depth of the intermediate landing should be at least the same as the width of the stairway, or greater. This ensures safety and adherence to accessibility standards, preventing long, uninterrupted flights of stairs.
About the full video
This video provides conceptual insights into designing and constructing staircases, focusing on critical aspects like guardrail layout, precise stringer measurements, and material compensation. It highlights best practices for ensuring structural integrity and adherence to building codes, which are essential for durable and aesthetically pleasing metal-supported stair frames.
Step 10 of 10: Evaluate Landing Requirements
Verify that landings are provided at the top and bottom of each flight of stairs. Ensure that any landing is at least as wide as the stairs it serves. If the stairs change direction, the landing must be at least as wide as the stair and also as long as the stair is wide. Check that landings are level and securely attached.
Every video in How to Check Your Stairs Against Building Code
Step 1: Measure Stair Rise
Step 2: Measure Stair Run
- 0:42–0:56 Measure and Verify Rise and Run
- 0:52–2:34 Measuring Rise and Run
- 2:00–2:24 Analyzing Stairway with Consistent Nosings (Correct Design)
Step 3: Check for Consistent Riser Height
- 0:31–1:01 Measure Riser Height and Tread Depth Consistency
- 4:28–6:49 Maximum Riser and Tread Difference
- 3:09–3:40 Set Riser Height and Consistency
Step 4: Check for Consistent Tread Depth (Run)
Step 5: Inspect Tread Nosing
Step 6: Check Stair Width
- 1:36–2:19 Minimum Stairway Width
- 1:34–2:22 Determine Overall Stair Width
- 0:00–0:40 Understand Minimum Stairway Width
Step 7: Inspect Handrails
- 0:24–0:42 Check Railing Height
- 4:07–4:38 Inspect Commercial Stair Handrails
- 1:50–2:05 Measure Handrail Height
Step 8: Inspect Balusters and Guardrails
- 5:28–6:08 Check Guardrail Openings
- 0:29–0:58 Measure Baluster Spacing for Code Compliance
- 0:25–0:29 Check Guardrail Opening Size
Step 9: Check Headroom
- 2:19–2:52 Minimum Headroom Height
- 0:40–1:12 Determine Minimum Headroom Height
- 10:28–12:22 Verify Fitment and Headroom in Space
Step 10: Evaluate Landing Requirements
- 12:40–15:25 Understand Landing Code Requirements (this video)
- 17:28–23:43 Identify Landing Size Requirements
- 6:03–6:46 Implement Landings
How to Check Your Stairs Against Building Code
This project outlines the process for a DIYer to check their existing stairs against common building code requirements. It involves understanding key measurements and features of stairs and comparing them to established standards. The goal is to identify any potential safety issues or code violations.
Read the full guide Browse all guides
Planning this project? Shop Oak Valley Designs.