Understand the crucial rule about uniformity in stair risers and treads: the maximum allowable difference between the smallest and the largest measurement for either risers or treads is 3/8 of an inch. The video provides examples for risers: if four risers are 7 inches, one is 6 7/8 inches, and another is 7 1/8 inches, the difference (1/4 inch) is acceptable. Even if one riser is 7 1/4 inches, the difference (3/8 inch from 6 7/8 inches) is still acceptable. However, if a riser is 7 3/8 inches, the difference becomes 1/2 inch (from 6 7/8 inches), which is unacceptable. This same principle of a 3/8-inch maximum difference applies to tread measurements as well (e.g., from 10 3/4 inches to 11 1/16 inches would be an acceptable 3/8-inch difference).
Goal: Ensure uniformity in stair riser and tread dimensions.
What's used
Tools
- Building Code Books
- Calculator
- Tape Measure
About the full video
This project offers a comprehensive guide for DIY enthusiasts on essential stair building codes based on the 2021/2022 International Residential Building Code. It systematically breaks down regulations concerning door swings over stairs, minimum stairway width, required headroom clearance, individual riser height limits, minimum tread depth, landing dimensions, allowable variations in riser and tread measurements, and exceptions for non-habitable attic and crawl space access. The goal is to provide a solid foundation of knowledge for planning and executing safe and compliant stair construction or renovation projects.
What's said in this clip
Here's another stair building code that can be confusing, but hopefully by the time you're done watching the video, it will not be anymore. And it has to do with the stair treads and risers and the difference, the maximum allowable difference by most building codes is going to be three eighths of an inch difference. Now, I will put a reference to the building code books or one of the building code books where I got this from. And remember that not all building departments around the world, these videos are watched all over the world. They are not always going to be the same, but they might be close. So, for example, our maximum distance is going to be three eighths of an inch between the smallest measurement and the largest measurement for treads and risers. In our first example, we have six risers, four of them are seven inches, one is six and seven eighths, and the other is seven and an eighth. And the smallest riser is six and seven eighths, the tallest one, seven and an eighth, the difference is a quarter of an inch. A situation like this would be acceptable because the difference between the smallest and the tallest is only a quarter of an inch. Here's another situation that would also be acceptable. We now have a seven and a quarter inch riser at the top, making it the tallest one. The difference between six and seven eighths and seven and a quarter is three eighths of an inch, so we're still fine here. However, if we raise this one to seven and three eighths of an inch, we now have a half inch difference between the smallest and the tallest riser. And this, of course, would be a situation that wouldn't be acceptable to most building departments. Now, the same principle applies to the steps, maximum difference between the smallest and the largest. In this case here, we have a half of an inch, something like this is not going to be acceptable by most building departments. However, a situation like this probably will. So if we take our smallest thread width or depth and the largest, we have three eighths of an inch difference.
Automatically transcribed from the source video.
Step 3 of 10: Check for Consistent Riser Height
Compare all the riser height measurements taken in Step 1. Building codes mandate that the difference in rise between any two consecutive steps should not exceed 3/8 inch. This uniformity is crucial for preventing missteps.
Every video in How to Check Your Stairs Against Building Code
Step 1: Measure Stair Rise
Step 2: Measure Stair Run
- 0:42–0:56 Measure and Verify Rise and Run
- 0:52–2:34 Measuring Rise and Run
- 2:00–2:24 Analyzing Stairway with Consistent Nosings (Correct Design)
Step 3: Check for Consistent Riser Height
- 0:31–1:01 Measure Riser Height and Tread Depth Consistency
- 4:28–6:49 Maximum Riser and Tread Difference (this video)
- 3:09–3:40 Set Riser Height and Consistency
Step 4: Check for Consistent Tread Depth (Run)
Step 5: Inspect Tread Nosing
Step 6: Check Stair Width
- 1:36–2:19 Minimum Stairway Width
- 1:34–2:22 Determine Overall Stair Width
- 0:00–0:40 Understand Minimum Stairway Width
Step 7: Inspect Handrails
- 0:24–0:42 Check Railing Height
- 4:07–4:38 Inspect Commercial Stair Handrails
- 1:50–2:05 Measure Handrail Height
Step 8: Inspect Balusters and Guardrails
- 5:28–6:08 Check Guardrail Openings
- 0:29–0:58 Measure Baluster Spacing for Code Compliance
- 0:25–0:29 Check Guardrail Opening Size
Step 9: Check Headroom
- 2:19–2:52 Minimum Headroom Height
- 0:40–1:12 Determine Minimum Headroom Height
- 10:28–12:22 Verify Fitment and Headroom in Space
Step 10: Evaluate Landing Requirements
- 12:40–15:25 Understand Landing Code Requirements
- 17:28–23:43 Identify Landing Size Requirements
- 6:03–6:46 Implement Landings
How to Check Your Stairs Against Building Code
This project outlines the process for a DIYer to check their existing stairs against common building code requirements. It involves understanding key measurements and features of stairs and comparing them to established standards. The goal is to identify any potential safety issues or code violations.