What happens in this clip
If stair treads are less than 11 inches deep, a nosing (overhang) is required. The nosing must protrude between 3/4 inch and 1 1/4 inches beyond the riser below. Additionally, the radius of the front edge of the nosing cannot exceed 9/16 inch to prevent a tripping hazard. Like other stair dimensions, the nosing depth must be consistent throughout a flight, with a maximum variance of 3/8 inch.
Goal: Apply nosing between 3/4 inch and 1 1/4 inch projection if treads are less than 11 inches deep, ensuring correct radius and minimal variance.
What's used
Tools
- Pencil
About the full video
This video provides a comprehensive overview of essential building codes and framing formulas for constructing safe and compliant stairs. It covers critical dimensions such as overall width, headroom, vertical rise, riser height, tread depth, nosing specifications, tread slope, landing requirements, and rules for winder stairs and open risers, emphasizing safety and legal compliance.
Step 5 of 10: Inspect Tread Nosing
The nosing is the projecting edge of the tread. Codes often specify that the nosing should not exceed a certain projection (typically 1 to 1.5 inches) and that the radius of the nosing should be consistent. Some codes may require that the bottom of the nosing should not extend beyond the face of the riser below it by more than 1/2 inch to prevent toe-catching.
Every video in How to Check Your Stairs Against Building Code
Step 1: Measure Stair Rise
Step 2: Measure Stair Run
- 0:42–0:56 Measure and Verify Rise and Run
- 0:52–2:34 Measuring Rise and Run
- 2:00–2:24 Analyzing Stairway with Consistent Nosings (Correct Design)
Step 3: Check for Consistent Riser Height
- 0:31–1:01 Measure Riser Height and Tread Depth Consistency
- 4:28–6:49 Maximum Riser and Tread Difference
- 3:09–3:40 Set Riser Height and Consistency
Step 4: Check for Consistent Tread Depth (Run)
Step 5: Inspect Tread Nosing
- 4:57–5:37 Specify Nosing Requirements (this video)
- 0:37–1:59 Analyzing Stairway Without Step Nosings (Deck Nosing Present)
- 2:00–2:24 Analyzing Stairway with Consistent Nosings (Correct Design)
Step 6: Check Stair Width
- 1:36–2:19 Minimum Stairway Width
- 1:34–2:22 Determine Overall Stair Width
- 0:00–0:40 Understand Minimum Stairway Width
Step 7: Inspect Handrails
- 0:24–0:42 Check Railing Height
- 4:07–4:38 Inspect Commercial Stair Handrails
- 1:50–2:05 Measure Handrail Height
Step 8: Inspect Balusters and Guardrails
- 5:28–6:08 Check Guardrail Openings
- 0:29–0:58 Measure Baluster Spacing for Code Compliance
- 0:25–0:29 Check Guardrail Opening Size
Step 9: Check Headroom
- 2:19–2:52 Minimum Headroom Height
- 0:40–1:12 Determine Minimum Headroom Height
- 10:28–12:22 Verify Fitment and Headroom in Space
Step 10: Evaluate Landing Requirements
- 12:40–15:25 Understand Landing Code Requirements
- 17:28–23:43 Identify Landing Size Requirements
- 6:03–6:46 Implement Landings
How to Check Your Stairs Against Building Code
This project outlines the process for a DIYer to check their existing stairs against common building code requirements. It involves understanding key measurements and features of stairs and comparing them to established standards. The goal is to identify any potential safety issues or code violations.
Read the full guide Browse all guides
Planning this project? Shop Oak Valley Designs.