Repeat for All Risers and Measure Variation
From How to Check Your Stairs Against Building Code · Step 1 of 10 · Video by stairbuilding

Showing 1:24–1:56 of the source video. Watch the full video with every moment.
What happens in this clip
Proceed step by step, moving the block to each subsequent riser. For each riser, place the block on the tread and against the riser. If the current tread height doesn't align with any previous mark on the block, make a new mark. You should now have multiple marks on your block, representing all the different riser heights encountered. Once you have checked all risers (down to the very bottom step), use a measuring tape or ruler to find the maximum difference between any two marks on your block. This measurement represents the overall riser height variation across your staircase.
Goal: Continue this process for every riser down the staircase, marking the block each time a new height is observed. Once all risers are checked, measure the total difference between the highest and lowest marks on the block.
What's used
Tools
- Measuring Tape or Ruler
- Scrap Lumber Block (with all marks)
About the full video
This video provides a simple, visual method to check the height variation of stair risers, ensuring compliance with common building codes that typically allow for a maximum of 3/8 inch variation between any two risers on a staircase. It demonstrates using a scrap block of wood to mark and compare riser heights from the top to the bottom of the staircase.
Step 1 of 10: Measure Stair Rise
Using a tape measure, accurately record the vertical distance from the top surface of one tread to the top surface of the adjacent tread. This measurement is known as the stair rise. Repeat this for every step to check for uniformity. Building codes typically require stair rises to be between 4 inches and 7 inches, and all rises within a single flight of stairs should be within 3/8 inch of each other.
Every video in How to Check Your Stairs Against Building Code
Step 1: Measure Stair Rise
- 0:31–1:01 Measure Riser Height and Tread Depth Consistency
- 0:42–0:56 Measure and Verify Rise and Run
- 1:24–1:56 Repeat for All Risers and Measure Variation (this video)
Step 2: Measure Stair Run
- 0:42–0:56 Measure and Verify Rise and Run
- 0:52–2:34 Measuring Rise and Run
- 2:00–2:24 Analyzing Stairway with Consistent Nosings (Correct Design)
Step 3: Check for Consistent Riser Height
- 0:31–1:01 Measure Riser Height and Tread Depth Consistency
- 4:28–6:49 Maximum Riser and Tread Difference
- 3:09–3:40 Set Riser Height and Consistency
Step 4: Check for Consistent Tread Depth (Run)
Step 5: Inspect Tread Nosing
Step 6: Check Stair Width
- 1:36–2:19 Minimum Stairway Width
- 1:34–2:22 Determine Overall Stair Width
- 0:00–0:40 Understand Minimum Stairway Width
Step 7: Inspect Handrails
- 0:24–0:42 Check Railing Height
- 4:07–4:38 Inspect Commercial Stair Handrails
- 1:50–2:05 Measure Handrail Height
Step 8: Inspect Balusters and Guardrails
- 5:28–6:08 Check Guardrail Openings
- 0:29–0:58 Measure Baluster Spacing for Code Compliance
- 0:25–0:29 Check Guardrail Opening Size
Step 9: Check Headroom
- 2:19–2:52 Minimum Headroom Height
- 0:40–1:12 Determine Minimum Headroom Height
- 10:28–12:22 Verify Fitment and Headroom in Space
Step 10: Evaluate Landing Requirements
- 12:40–15:25 Understand Landing Code Requirements
- 17:28–23:43 Identify Landing Size Requirements
- 6:03–6:46 Implement Landings
How to Check Your Stairs Against Building Code
This project outlines the process for a DIYer to check their existing stairs against common building code requirements. It involves understanding key measurements and features of stairs and comparing them to established standards. The goal is to identify any potential safety issues or code violations.